How Vert-X filters fume
Air passes through each stage in order.
1
Spark Arrestor
Catches sparks and hot particles before they reach the filter media. Washable and reusable.
2
Pre-Filter (F9)
Takes the coarse and fine particulate so the HEPA only handles what gets past it. Cheaper to replace, which is the point. F9 equals MERV 16.
3
HEPA (H14)
Captures the ultrafine submicron particulate that reaches deep into the lungs.
4
Chemical Cartridge (optional)
The only stage that handles gases. Carbon adsorbs VOCs and odors that particle filters cannot.
High-Velocity Fume Capture in Action
Effective source capture removes hazardous welding fumes before they spread through the workspace. Designed to help maintain air quality standards while improving overall shop safety and comfort.
Applications
-
Laser Welding
Traditional Handheld Welding
Soldering
Rust and Paint Removal
-
Laser Welding
Traditional Handheld Welding
Soldering
Rust and Paint Removal
-
Laser Welding
Traditional Handheld Welding
Soldering
Rust and Paint Removal
-
Laser Welding
Traditional Handheld Welding
Soldering
Rust and Paint Removal
-
Laser Welding
Traditional Handheld Welding
Soldering
Rust and Paint Removal
-
Laser Welding
Traditional Handheld Welding
Soldering
Rust and Paint Removal
-
Laser Welding
Traditional Handheld Welding
Soldering
Rust and Paint Removal
-
Laser Welding
Traditional Handheld Welding
Soldering
Rust and Paint Removal
Questions about Vert-X
What does a welding fume extractor actually do?
Welding and laser welding generate ultrafine particulate that stays airborne and is small enough to be inhaled deep into the lungs. A fume extractor captures that particulate at the source, filters it, and returns clean air to the shop. Source capture is the key part. Pulling fume at the arc is far more effective than trying to filter a whole room after it has already dispersed.
Why is Vert-X wall-mounted instead of floor-standing?
Floor space is usually the scarcest thing in a welding cell. Mounting on the wall frees the footprint a floor unit would take and keeps the extraction arm up out of the way of the work. The lightweight arm stays where you put it without sagging, and the oversized 8 inch duct keeps airflow high across a wide capture zone. Same 1200 CFM as the floor-standing Weld-RX, just using vertical space instead.
Can I use this indoors without outside exhaust?
Yes. Every Filtrabox unit is designed for indoor use with no outdoor ventilation required. Air is captured at the source, filtered, and recirculated back into the workspace, which means no ducting through a wall or roof and no conditioned air being pumped outside. One thing to confirm for your process: recirculation depends on the filtration matching what you produce. Particulate is handled by the standard configuration, and gases or VOCs require the carbon cartridge.
Does it remove gases and VOCs, or only particles?
Pre-filters and HEPA filters capture particles. They do not remove gas-phase contaminants. If your process produces gases, odors, or VOCs, you need the activated carbon chemical cartridge, which adsorbs them. Most welding and laser welding is a particulate problem, so the standard configuration is usually the right one. Processes involving coatings, plastics, or chemicals are where carbon matters.
What is the difference between a pre-filter and a HEPA filter?
They do different jobs and they are not interchangeable. The pre-filter takes the coarse and fine particulate first, so the HEPA only has to deal with what gets past it. The HEPA then captures the ultrafine submicron material at 99.999% efficiency on 0.3 micron particles. Because the pre-filter absorbs most of the loading, it is the element you replace more often, and it is the cheaper of the two. That is by design.
Can the filters be cleaned instead of replaced?
The steel mesh spark arrestor is washable and reusable, so that one gets cleaned rather than replaced. The pre-filter and HEPA cannot be cleaned. Attempting to blow out or wash filter media damages the fibers and destroys the efficiency rating, which defeats the purpose of having a HEPA in the first place. Those are replacement items.
How often do the filters need to be replaced?
There is no fixed interval, because filter life depends on what you weld, how much, and at what duty cycle. A shop running production all day loads filters far faster than one welding a few hours a week, and heavier particulate processes load them faster still. Rather than guess at a calendar, watch the pressure gauge. Rising pressure across the filter means it is loading up and approaching replacement. The pre-filter is designed to be the element you change most often, which protects the more expensive HEPA behind it.
Which Filtrabox welding extractor should I choose?
All three move 1154 to 1200 CFM, so airflow will not decide it. How and where you work will. Nomad is the one that leaves the building, at 154 lbs with a 30 inch doorway clearance for field service and mobile crews. Weld-RX is the shop workhorse, on casters so it repositions around the floor, with the largest filter area in the line at 22 m2 for high duty cycle work. Vert-X mounts on the wall and gives up mobility entirely in exchange for zero floor space. Contact the factory if you are unsure, since duty cycle and application matter more than the headline airflow number.
Who is Vert-X designed for?
Vert-X is built for welding cells where floor space is the constraint. It mounts on the wall, so it takes no footprint and keeps the extraction arm up out of the work area. The oversized 8 inch duct maintains 1200 CFM across a wide capture zone, matching the floor-standing Weld-RX on airflow while using vertical space instead. It ships with F9 pre-filtration and a 99.999% HEPA as standard, with an optional carbon cartridge when the process produces gases rather than just particulate.
Ideal for
- Welding cells with limited floor space
- Permanent workstation installations
- Laser welding and conventional welding
- Processes needing optional gas-phase filtration